Commercial scenario

Multi-family window replacement, one elevation at a time

A repeating punched-opening pattern across an occupied apartment building is the most common commercial scope in this corridor. Here is how that work is actually scoped, sequenced, and specified.

Request a Quote

Scope at a glance

Buyer
Property manager, owner's rep, or general contractor
Scope driver
Unit takeoff per elevation, by opening size and type
Typical units
Fixed, casement, and hopper combinations in a repeating pattern
Code focus
Egress at sleeping rooms, U-factor and SHGC per the energy code

This page describes a representative scope for this project type. It is not a claim about a specific completed job, and no client, address, or date is implied.

Brick multi-family building elevation with repeating punched-opening aluminum windows across four floors

The takeoff comes first

Before anything is priced, the openings get counted and grouped. Two apartments that look identical from the sidewalk frequently have different rough openings once the original construction tolerances are measured, so the takeoff records actual dimensions per opening rather than a nominal size repeated down the elevation.

The result is a unit schedule: each opening gets a type mark, a size, a glazing package, and an operation. That schedule becomes the fabrication order and the install checklist, which is why the quote form asks for opening counts and elevation counts rather than square footage.

Sequencing an occupied building

Residents stay in place. That constrains the work far more than the product does: units are removed and replaced within a single working day per apartment, interior protection goes down before the old frame comes out, and the elevation moves in a predictable direction so notices can be posted in advance.

Weather exposure is the other constraint. Openings are not left open overnight, which means the daily unit count is set by how many can be closed out the same day, not by how many can be demolished.

Where code enters

Any window serving a sleeping room has to satisfy egress clear-opening requirements after replacement, not before. A replacement unit installed inside the existing frame reduces the clear opening, which is the single most common way a like-for-like swap fails inspection in a multi-family building.

Clear opening
Measured on the new operable unit, not the masonry opening.
Thermal
U-factor and SHGC targets for the applicable climate zone.
Air and water
Tested assemblies with documented performance ratings.

Scope your version of this

Every project differs in opening count, condition, and timing. The quote form takes it from there.